检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:吴慧娟[1] 任泽钦[1] 鲍永珍[1] 侯宪如[1] 胡亦文[1]
机构地区:[1]北京大学人民医院眼科,100044
出 处:《中华眼科杂志》2010年第12期1110-1114,共5页Chinese Journal of Ophthalmology
基 金:国家863课题(2007AA032427)
摘 要:目的 评价Pentacam 眼前节分析系统的临床应用价值.方法 自身对照研究.33例(61只眼)原发性闭角型青光眼和原发性房角关闭患者,在接受掺钕钇铝石榴石激光周边虹膜切除术前及术后,应用Pentacam眼前节分析系统进行眼前节摄像和图像分析,同时分别测定患者眼前房相关量化指标.激光周边虹膜切除术前后各检测参数的变化比较采用配对t检验.结果 Pentacam眼前节分析系统能够清晰显示激光治疗前后眼前节结构变化,如虹膜变平坦及周边前房加深.患者术后平均眼前房容积(94.10±18.42)mm3(t=-15.928);最小前房角(24.93±4.53).(t=-5.087);周边前房深度:颞侧(1.23±0.23)mm(t=-17.399),上方(1.03±0.20)mm(t=-10.629),鼻侧(0.99±0.21)mm(t=-12.576),下方(1.16±0.24)mm(t=-14.474);上述参数与术前比较均明显增加,差异有统计学意义(均P<0.01).其中前房容积从术前的(74.10±16.35)mm3增加到术后的(94.10±18.42)mm3,周边前房深度的增加幅度为0.17 mm(鼻侧)至0.29 mm(颞侧);而中央前房深度较术前无明显增加.结论 Pentacam眼前节分析系统可定性和定量反映原发性闭角型青光眼和原发性房角关闭眼激光周边虹膜切除术后前房形态和参数的变化.Objective To evaluate the anterior segment parameters in early primary angle-closure glaucoma (PACG) and primary angle closure (PAC) eyes before and after neodymium: yttrium aluminum garnet (Nd:YAG) laser periphery iridectomy (LPI) by using Pentacam system. Methods Self-coutrol study. Sixty one eyes of 33 patients were recruited into this study. The images of the anterior segment of the eye were captured and the parameters[I.e. The anterior chamber ( AC ) volume, the central AC depth, the peripherial AC depth, the peripherial AC angle and the pupil size]were measured by the Pentaeam system pre-operatively and 1 week after laser treatment. Results The Pentacam system clearly showed the structure changes of the anterior segment after LPI ( I. E. The convex configuration of the iris was flattened and the peripherial AC depth was deepened). The average AC volume( t = 15. 928 ), the peripherial AC depth( t =- 17. 399, - 10. 629, - 12. 576, - 14. 474 ) and the peripherial AC angle( t = - 5. 087 ) were increased significantly (P 〈0. 01 ) after LPI. The AC volume was (74. 10 ± 16.35 ) mm3 before LPI and (94. 10 ±18.42) mm3 after LPI, and the increases of peripherial AC depth were 0. 17 mm (nasal) and 0. 29 mm (temporal). There was no statistical significant changes in the AC depth before and after LPI. Conclusion In patients with PACG and PAC, the changes of AC after LPI can be demonstrated by the Pentacam qualitatively and quantitatively.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.229