摘  要:选取薄板弯曲控制微分方程的24类特解序列组合构造挠度试函数。根据玻璃幕墙风荷载和室内外温差作用的组合荷载,建立边界型最小二乘法公式及程序,同时提出了幕墙玻璃板平面内变形的可能性。The deflection trial function is formed by the 24 kinds of particular solutions of the elastic plate _bending control differential equation. According to the combined load of wind load and temperature action caused by temperature differencebetween indoor and outside, a formula and a computer program are found with the least square boundary collocation method. In addition, the probability of plane deformation of glass curtain wall is presented to furnish as a reference to designing.