Measurement of integral diffraction coefficients of crystals on beamline 4B7 of Beijing Synchrotron Radiation Facility  被引量:1

Measurement of integral diffraction coefficients of crystals on beamline 4B7 of Beijing Synchrotron Radiation Facility

在线阅读下载全文

作  者:杨家敏 甘新式 赵阳 崔明启 朱托 赵屹东 孙丽绢 郑雷 鄢芬 胡智民 韦敏习 张继彦 易荣清 

机构地区:[1]Research Center of Laser Fusion,Chinese Academy of Engineering Physics [2]Institute of High Energy Physics,Chinese Academy of Sciences

出  处:《Chinese Physics B》2011年第1期276-283,共8页中国物理B(英文版)

基  金:Project supported by the Foundation of National Key Laboratory of High Temperature and Density Plasma Physics(Grant No.9140C6804020704);the National Natural Science Foundation of China(Grant No.10874156);one of the authors,GanXin-Shi,was also partially supported by the School of Physical Science and Technology in Sichuan University,China

摘  要:Integral diffraction coefficients of the crystal are the essential data of a crystal spectrometer which is extensively used to measure quantitative x-ray spectra of high temperature plasmas in kilo-electron-volt region. An experimental method has been developed to measure the integral diffraction coefficients of crystals on beamline 4B7 of Beijing Synchrotron Radiation Facility. The integral diffraction coefficients of several crystals including polyethylene terephthalate (PET), thallium acid phthalate (T1AP) and rubidium acid phthalate (RAP) crystals have been measured in the x-ray energy range 2100-5600 eV and compared with the calculations of the 'Darwin Prins' and the 'Mosaic' models. It is shown that the integral diffraction coefficients of these crystals are between the calculations of the 'Darwin Prins' and the 'Mosaic' models, but more close to the 'Darwin Prins' model calculations.Integral diffraction coefficients of the crystal are the essential data of a crystal spectrometer which is extensively used to measure quantitative x-ray spectra of high temperature plasmas in kilo-electron-volt region. An experimental method has been developed to measure the integral diffraction coefficients of crystals on beamline 4B7 of Beijing Synchrotron Radiation Facility. The integral diffraction coefficients of several crystals including polyethylene terephthalate (PET), thallium acid phthalate (T1AP) and rubidium acid phthalate (RAP) crystals have been measured in the x-ray energy range 2100-5600 eV and compared with the calculations of the 'Darwin Prins' and the 'Mosaic' models. It is shown that the integral diffraction coefficients of these crystals are between the calculations of the 'Darwin Prins' and the 'Mosaic' models, but more close to the 'Darwin Prins' model calculations.

关 键 词:integral diffraction coefficient CRYSTAL x-ray spectrum measurement high temperature plasmas 

分 类 号:O434.1[机械工程—光学工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象