检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张磊[1] 张妍[1] 李敏[1] 毛燕燕[1] 车焱[1] 周维谨[1]
出 处:《中国计划生育学杂志》2011年第1期10-17,共8页Chinese Journal of Family Planning
基 金:"十一五"国家科技支撑计划"农村卫生服务适宜技术收集与应用"课题(2007BAI07A01);国家人口计生委三大工程C1项目"避孕节育/生殖健康适宜技术的循证评估"课题(C-70)
摘 要:目的:评价GyneFix330与TCu220C、TCu380A宫内节育器(IUD)的有效性、副反应和续用情况。方法:电子和手工检索1990年1月~2009年11月中英文发表的相关文献,按循证医学方法对纳入文献进行分析评价。结果:纳入26篇正式发表的随机对照临床试验文献。与TCu220C IUD相比,GyneFix330IUD的12个月和24个月带器妊娠率和脱落率较低;6个月、12个月和24个月的经期延长、经量增多、腰腹痛和不规则出血发生率较低;12个月因症取出率较低,续用率则较高。GyneFix330和TCu380A IUD12个月、24个月、36个月和9年的带器妊娠率均低于2.50/100妇女。两组6个月、12个月、24个月和36个月的月经量增多、白带增多和不规则出血发生率互有优劣。与TCu380A IUD相比,Gyne-Fix330IUD12个月和24个月的因症取出率接近,续用率略高。结论:GyneFix330IUD临床应用效果优于TCu220C IUD,与TCu380A IUD相差不大,仍需长期大样本临床观察予以确证。Objective:To explore the effectiveness,side effects,and the continuation rates of GyneFix330 and TCu220C and TCu380A intrauterine devices(IUDs).Methods:Electronic and hand searches were used to identify relevant literature published in Chinese and English between January 1990 and November 2009.Relevant papers were evaluated and selected according to the criteria of evidence-based medicine.Results:A total of twenty-six randomized controlled clinical trials(RCTs)were included in this review.Compared with TCu220C IUD,GyneFix330 IUD had lower expulsion and pregnancy rates with IUD in situ at 12 months and 24 months of use;while it was less likely to introduce prolonged menstrual bleeding,heavy menstrual bleeding,irregular vaginal bleeding and low back-abdominal pain during 6,12 and 24 months of the observation,and lower rate of discontinuation due to medical reasons and higher continuation rate at 12 months of use.The one-year,two-year,three-year and nine-year pregnancy rates with IUD in situ of both GyneFix330 and TCu380A IUDs were lower than 2.50 per hundred women.The likelihood of increasing duration of menstrual bleeding,heavy menstrual bleeding and irregular vaginal bleeding was similar between GyneFix330 and TCu380A IUDs.The removal rate due to medical reasons of GyneFix330 IUD was similar to that of TCu380A IUD.However,the continuation rate of GyneFix330 IUD was slightly higher than its counterpart.Conclusion:The effectiveness,side effects and continuation rate of GyneFix330 IUD were similar to those of TCu380A IUD.These measurements were demonstrated to be better for Gynefix330 IUD than for TCu220C IUD.However,more large-scale RCTs with high quality of research need to be done to confirm this conclusion.
关 键 词:GyneFix330 TCU220C TCU380A 系统评估 META分析
分 类 号:R169.4[医药卫生—公共卫生与预防医学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:52.14.244.195