检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]连云港金康医药科技有限公司,江苏连云港222115 [2]东南大学化学化工学院,江苏南京211189
出 处:《化工时刊》2011年第1期14-17,共4页Chemical Industry Times
摘 要:对电子产品中多溴二苯醚(PBDEs)的测定方法进行了研究。样品采用甲苯作为提取溶剂进行索氏萃取,提取液经过净化、硅胶柱分离、浓缩处理。再用带电子捕获检测器的气相色谱仪(GC-ECD)进行测定。对GC-ECD的精确度和回收率进行了测定,基质加标空白回收率在87.3%~116.3%。并测得相对标准偏差(RSD)为2.95%~4.01%,方法检出限为0.6~10.4 mg.kg-1。A fast and effective method for measuring concentrations of polybrominated diphenyl ethers(PBDEs) in electronic products was developed.Toluene was used as a solvent for Soxhlet extraction to extract the samples.After purification,silica gel column separation and enrichment,the extracted PBDEs in the solvent phase were transferred to the l mL sample for analysis by GC-ECD.Recovery of those PBDEs spiked in several blanks ranged from 87.3% to 116.3%with a relative standard deviation of 2.95% to 4.01%.The detection limit of the GC-ECD determination was 0.6~10.4 mg·kg-1.The method was successfully employed for measurement of Nona-BDE and Deca-BDE in the sample.
分 类 号:TN06[电子电信—物理电子学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.31