检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:黄廷辉[1] 吴涛[1] 庞顺[1] 胡洪华[1] 相里红波
机构地区:[1]西安热工研究院有限公司,陕西西安710032 [2]山西太钢不锈钢股份有限公司,山西太原030003
出 处:《热力发电》2011年第1期1-3,15,共4页Thermal Power Generation
摘 要:针对太钢自备电厂母管制燃煤、燃气锅炉系统,建立了燃煤、燃气锅炉特性和锅炉负荷优化分配模型。对现场运行数据的优化计算表明,优化后与优化前相比,当锅炉蒸发量大于520 t/h时,可以节约燃煤0.131 t/h;当锅炉蒸发量小于520 t/h时,可以节约燃气30 838.44 m3/h。提出的燃煤、燃气锅炉负荷优化分配方法,适用于母管制锅炉系统的负荷优化分配。Directing against the header system of coal/gas fired boiler in self-supply power plant of Taiyuan Iron and Steel Corporation,a model of boiler behavior and for optimization in boiler load distribution has been established.The optimized calculation of operation data in the field shows that the fuel coal can be saved 0.137 t/h in the event of evaporation capacity needed by the boiler being greater than 520 t/h after optimization;the fuel gas can be saved 30838.44 m3/h in the case of evaporation capacity needed by the boiler being less than 520 t/h.The above-mentioned optimization method for boiler load distribution is suitable to load distritution optimization for boilers with header system.
分 类 号:TK222[动力工程及工程热物理—动力机械及工程]