检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]湘潭大学化工学院,湘潭411105
出 处:《理化检验(化学分册)》2011年第1期81-83,共3页Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
摘 要:提出了采用HK 200型磨样机制样,直读光谱法测定生铁中硅、锰和磷的含量。探讨了基体效应、狭缝位置、分析条件和制样方法等影响因素。在优化的试验条件下,3种元素的相对标准偏差(n=11)均小于5%。方法用于生铁试样分析,测定结果与X射线荧光光谱法和分光光度法的测定结果基本一致。The sample was prepared with HK 200 sample grinder,and contents of Si,Mn and P in the sample were determined by the direct-reading spectrometer.Influential factors,including matrix effect,position of slit,analytical conditions and method of sample preparation were discussed.Under the optimized experimental condition,values of RSD′s(n=11) of the 3 elements found were less than 5%.The proposed method was applied to analysis of sample of pig iron,and the results obtained were in conformity with those by XRFS and spectrophotometry.
正在载入数据...