用分光光度方法测定建筑材料表面的太阳光-热参数  

DETERMINING SUNLIGHT-THERMAL PARAMETERS OF BUILDING MATERIALS SURFACE WITH SPECTROPHOTOMETRIC METHOD

在线阅读下载全文

作  者:张牛牛[1] 

机构地区:[1]常州大学建筑环境与设备工程研究室,常州213016

出  处:《太阳能学报》2011年第2期180-184,共5页Acta Energiae Solaris Sinica

摘  要:利用分光光度计对建筑材料表面,对紫外到近红外线范围(240~15000nm)内的正分光透射比、正分光反射比进行测定。另外,还利用积分球对紫外到红外线范围(240~2200nm)内的漫射比谱进行测定,同时将测定结果与正分光透射比、反射比进行比较,并计算出太阳吸收比及热放射比。The normal transmittance and near normally specular reflectance of ultra-violet, visible and infrared area (240- 15000nm) for building material surface were measured with spectropnotometer, and the diffusion spectrum of transmittance and reflectance of ultra-violet, visible and infrared area (240-2200nm) were measured with integrating sphere The result was compared with the normal transmittance and the normal spectrum reflectance. Based on the measurement resuit, the absorption and emission ratio of solar radiation was calculation and studied.

关 键 词:分光透射比 分光反射比 太阳吸收比 

分 类 号:TU83[建筑科学—供热、供燃气、通风及空调工程]

 