检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]西安科技大学电气与控制工程学院,陕西省西安市710054 [2]华中科技大学电气与电子工程学院,湖北省武汉市430074
出 处:《电网技术》2011年第3期119-123,共5页Power System Technology
基 金:陕西省教育厅专项科研计划项目(09JK603)
摘 要:传统矿井电网单相漏电的各序网络模型只能描述单相漏电的稳态特征,为此采用瞬时对称分量法建立了矿井电网单相漏电瞬时序网络模型,该模型可用于分析单相漏电的暂态和稳态特征,并利用该模型给出了单相漏电的瞬时零序电压和瞬时零序电流的数学表达式,可为单相漏电保护研究提供参考。Traditional sequence network models of mine distribution network can but describe steady state characteristic of single-phase leakage of this network, for this reason by use of instantaneous symmetrical component an instantaneous sequence network model of single-phase leakage in mine distribution network is built. The proposed model can be used to analyze transient and steady state characteristics of single-phase leakage, and based on this model the mathematical expressions of instantaneous zero sequence voltage and zero sequence current under single-phase leakage, which is available in the research on single-phase leakage protection, are deduced.