镍离子对分光光度法测定水样中COD的影响  

Effect of nickel ions on COD determination in water samples by spectrophotometry

在线阅读下载全文

作  者:李广超[1] 吴宏[1] 卢菊生[1] 

机构地区:[1]徐州师范大学化学化工学院,江苏徐州221116

出  处:《工业水处理》2011年第2期69-70,88,共3页Industrial Water Treatment

基  金:江苏省自然科学基金(BK2008121);徐州师范大学自然科学基金

摘  要:通过测定Cr3+、Cr2O72-和Ni2+的吸收曲线及标准水样的COD,研究了Ni2+对分光光度法测定COD的影响。结果表明,当水样中Ni2+质量浓度<100mg/L时,对测定结果无明显影响;若水样中Ni2+质量浓度>100mg/L时,应将水样稀释后再进行测定。The effect of nickel ions on COD determination by spectrophotometry has been studied based on the determination of absorption curves of Cr3+、Cr2O72-and Ni2+,and the COD of standard water samples.The results show that nickel ions have no effect on COD determination,if the concentration of nickel ions is less than 100 mg/L in the water sample.If the concentration of nickel ions is more than 100 mg/L,the COD of the water samples should be determined after the samples have been diluted.

关 键 词:化学需氧量 分光光度法 镍离子 

分 类 号:O657.32[理学—分析化学]

 