Tenax-TA吸附剂检测室内空气中苯浓度的影响因素分析  被引量:5

Analysis on Influence Factors of Detecting Benzene in the Indoor Air Using Tenax-TA Absorption

在线阅读下载全文

作  者:黄翠华 梅爱华 何小军[2] 杨玉华[2] 

机构地区:[1]广州市建筑科学研究院有限公司,广东广州510440 [2]深圳市建设工程质量检测中心,广东深圳518031

出  处:《工程质量》2011年第2期78-80,共3页Construction Quality

摘  要:通过测定苯回收率的方法探讨了使用Tenax-TA吸附剂检测室内空气中苯浓度的影响因素,如样品浓度、Tenax-TA试剂重量、采样温度、采样流速、采样体积等。试验结果表明,在一定浓度范围内,样品浓度不影响苯回收率;采样流速对苯回收率影响较小;而Tenax-TA试剂重量、采样温度和采样体积对苯回收率影响显著。Based on testing benzene reclaim ratio, the influence factors of detecting benzene in the indoor air using Tenax-TA absorption was discussed, such as benzene concentration, weight of Tenax-TA reagent, indoor temperature, velocity, air volume and so on. The experiment results indicated that benzene concentration had no effect on the recovery rate of benzene when the benzene concentration was low, the recovery rate of benzene affected by the velocity is slightly,but the weight of Tenax-TA, indoor temperature and air volume affected are evident.

关 键 词: Tenax—TA 室内空气 

分 类 号:TU502.2[建筑科学—建筑技术科学]

 