出 处:《海南医学》1999年第4期222-223,共2页Hainan Medical Journal
摘 要:目的:分析单泵膜式血浆置换(PE)治疗患者11例16次临床疗效。方法:用单一金宝血泵或金宝AK—10血透机血泵替代血浆置换机,用YT-50-PP及川澄KPS-0.5血浆分离器对11例病人行16次膜式PE,记录血浆置换速度、泵速,观察临床疗效。结果:16例次PE均顺利完成,各技术参数符合膜式PE理论要求,临床疗效好,与国内外同类报道吻合。结论:膜式PE对免疫性疾病的疗效显著;单泵膜式PE是实施膜式PE的可行、简捷手段。Objective: To analyze the effect on 11 cases patients 16 times of single pump membranefiltration plasma exchange. Methods: To Apply single Gambro blood pump or blood pump of Gambro AK - 10 hemodialysis machine substitude plasma exchange machine, YT - 50 - PP and KPS - 0.5 plasma seperator, 11 cases patients got 16 times membranefiltration PE. The plasma exchange speed and blood pump speed were recorded. ReSults: Sixteen times PE were finished seccessully.The index qualified the theoretic demands of membranefiltration PE. Clinic effet was very good as reported within china and abroad. Conclusion: Membranefiltration PE have Obvious effect on immune involved diseases. Single pump membranefiltration PE is a simple, convenient, feasible PE meathod.