检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李姗姗[1] 熊超[1] 吴亦农[1] 党海政[1]
机构地区:[1]中国科学院上海技术物理研究所,上海200083
出 处:《低温与超导》2011年第3期4-7,共4页Cryogenics and Superconductivity
摘 要:为了提高低温制冷机整机效率,基于力的平衡及电压平衡方程理论,分析了线性压缩机电机效率及电功转化为活塞表面声功效率的影响因素;并对线性压缩机效率进行了实验测量;理论与实验吻合较好;电机效率、电功转化为声功效率测量值与理论值偏差分别在3%及7%以内。最后对冷指确定时线性压缩机的优化设计方法进行了总结。In order to increase the total efficiency of the Stirling cryocooler and Stirling - type pulse tube cryocooler, theoretical analysis was carried out on the efficiency of the motor and transduction efficiency of electrical power to acoustic power at the piston surface of the linear compressor based on the force balance and voltage balance equation. The two efficiencies of two different linear compressors connected with cold fingers were measured. The calculated results agreed well with the test values, and the differences between the experimental results and the theoretical values were respectively 3% for the efficiency of the motor and 7% for the transduction efficiency of electrical power to acoustic power at the piston surface of the linear compressor. At last the optimal.design method of the linear compressor with known load impedance was summarized.
分 类 号:TB651[一般工业技术—制冷工程]