检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:马玲[1] 关忠谊[1] 吴健敏[1] 黄红梅[1] 张启模[1,2] 蒋维维[2]
机构地区:[1]广西兽医研究所,南宁530001 [2]广西大学动物科学技术学院,南宁530005
出 处:《南方农业学报》2011年第2期205-208,共4页Journal of Southern Agriculture
基 金:广西创新能力建设项目(08-05-01D);广西基本科研业务费专项项目(桂兽研专项08-4)
摘 要:【目的】建立一种简便、快速、精确的氯霉素(CAP)残留检测方法。【方法】在常规两步式化学发光酶免疫法(CLEIA)的基础上,同时加入一抗和二抗,并进一步优化抗原包被条件、抗体工作浓度、竞争反应时间等试验参数,建立了检测CAP残留的一步式CLEIA。【结果】该方法最佳检测范围为0.045~128μg/L,检测灵敏度达3.16μg/L,最低检测限为0.01μg/L,可检出国际规定的CAP残留标准底限值以下的残留量。与常规两步法相比,在不影响检测限和灵敏度的前提下,可缩短反应时间1.5h。【结论】采用一步式CLEIA检测CAP残留,与常规两步式CLEIA的检测效果相近,且耗时短,更符合快速检测的要求。[Objective]The present study was aimed to establish a convenient, rapid and accurate method for detection of residual chloramphenicol (CAP). [Method]Based on conventional two-step chemiluminescent enzyme immunoassay (CLEIA), the two antibodies were added to solution at the same time, and the antigen coating conditions, antibody concentration, competitive reaction timing, etc., were optimized to establish one-step competitive indirect chemiluminescent enzyme immunoassay. [Result]The established one-step CLEIA was utilized to detect the CAP, and the best detection was found in range of 0.045-128.000 μg/L with 3.16 μg/L detection sensitivity, and 0.01 μg/L lowest detection limit. This method could detect the CAP residual value even below the lowest limit of international standard. As compared to the two- step CLEIA, one-step CLEIA could lessen 1.5 hour of reaction time on the premise of no effects on detection limit and sensitivity. [Conclusion ]The established one-step CLEIA method produced the same quality of detection results for residual CAP as produced by two-step CLEIA, while it has advantage of taking lesser time compared to the later one.
关 键 词:氯霉素 一步式化学发光酶免疫法 灵敏度(IC50) 残留
分 类 号:TS251.7[轻工技术与工程—农产品加工及贮藏工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.3