运用除铁器清除煤中覆铜雷管  

Removal of copper-covered detonators by a tramp-iron remover

在线阅读下载全文

作  者:樊海龙 郭江泉 

机构地区:[1]大同中煤出口煤基地建设有限公司,山西大同037037

出  处:《煤炭加工与综合利用》2011年第1期37-39,67,共3页Coal Processing & Comprehensive Utilization

摘  要:介绍了除铁器的工作原理及煤中覆铜雷管的特征,理论上分析了利用除铁器吸出煤中覆铜雷管所需的磁场强度与煤流厚度之间的关系,计算得出,要想彻底清除煤流中覆铜雷管必须配备额定磁场强度不低于1500gs、表面磁场强度实测不低于3000gs的除铁器。Introduced are the tramp-iron remover and characteristics of copper-covered detonator mingled in coal;theoretically analyzed was the relationship between the necessary magnetic field strength and thickness of coal flow for picking up of a copper-covered detonator mingled in it;for thorough removal of copper-covered detonator within coal flow,the rated magnetic field strength of the tramp-iron remover should be not less than 1 500 gs,and the measured surface magnetic field strength,not less than 3 000 gs.

关 键 词:煤炭 除铁器 覆铜雷管 磁场强度 

分 类 号:TD941[矿业工程—选矿]

 