机构地区:[1]无锡市高速分析仪器厂,无锡214151 [2]西安理工大学
出 处:《理化检验(化学分册)》1999年第7期291-292,共2页Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
摘 要:选择活化剂用于电导法测定碳量.发现其吸收好,灵敏度高(可达10^(-4)%数量级),测试范围宽.测定碳量在0.062%~5.03%之间的铁合金,结果精密度好、准确度高.A new and effective activator is prepared and tested for the complete absorption of the CO_2 evolved. It is proved that through the use of this new activator, quantitative absorption of CO_2, high sensitivity (with the detection limit approaching w_c 10^(-1)%) and wider concentration range for carbon determination (w_c 0. 06% ~ 5. 00%) were achieved. The proposed method has been used for the determination of carbon and sulfur in several ferroalloy standard samples with satisfactory results.
分 类 号:TG141[一般工业技术—材料科学与工程]