Fenton氧化-曝气生物滤池处理纤维板废水的试验研究  被引量:6

EXPERIMENTAL RESEARCH ON TREATMENT OF FIBREBOARD WASTEWATER BY FENTON REAGENT-BAF PROCESS

在线阅读下载全文

作  者:武彦巍[1] 买文宁[1] 

机构地区:[1]郑州大学水利与环境学院,河南郑州450002

出  处:《水处理技术》2011年第4期123-126,共4页Technology of Water Treatment

摘  要:对Fenton氧化-曝气生物滤池处理纤维板厂好氧出水进行系统研究。试验表明,在FeSO4.7H2O投加量为0.003 mol·L-1,进水pH为5.0,n(H2O2)/n(Fe2+)为2:1,反应时间为2 h的条件下,Fenton试剂对COD的去除率可以达到65%以上,出水BOD5/COD提高到0.36。氧化后废水进入曝气生物滤池进行生化处理,组合工艺对COD的去除率可达到85%,日运行费用为2.064元.t-1水。In this paper, aeration tank effluent of fibreboard plant with Fenton reagent - BAF treatment method is studied systematically. Experiment result shows: the optimum removal rate of COD reached over 65%, with the dosage of FeSO4-7H20 0.003 mol·L^-1, influent pH 5.0,n (H2O2)/n(Fe^2+) 2:1, reaction time 2 h, effluent BOD5/COD rose to 0.36. After oxidation, wastewater enter into the BAF for biochemical treatment. The COD removal rate of combined process come to 85%. Day running cost is 2.064 yuan-t^-1 wastewater.

关 键 词:FENTON试剂 曝气生物滤池 纤维板 正交试验 好氧出水 

分 类 号:X783.5[环境科学与工程—环境工程]

 