Peroxyoxalate Chemiluminescence Based on Fluorescent Conjugated Polymer for the Determination of Triton X-IO0  被引量:1

Peroxyoxalate Chemiluminescence Based on Fluorescent Conjugated Polymer for the Determination of Triton X-IO0

在线阅读下载全文

作  者:Jin, Yingqiong Sun, Lilin Hao, Dan Yu, Rui Qian, Zhangsheng Zhu, Changqing 

机构地区:[1]Anhui Key Laboratory of Chemo-Biosensing, College of Chemistry and Materials Science, Anhui Normal University, Wuhu, Anhui 241000, China

出  处:《Chinese Journal of Chemistry》2011年第3期575-580,共6页中国化学(英文版)

基  金:Project supported by the National Natural Science Foundation of China (No. 20875003).

摘  要:A novel peroxyoxalate chemiluminescence system has been designed for the determination of Triton X-100 (TX-100), in which a hydrophobic fluorescent conjugated polymer, poly[2,5-bisnonyloxy-1,4-phenyleneethynylene-9,10-anthrylene] (PPEA) was employed as a fluorophor. A strong enhanced intensity of chemiluminescence (CL) was observed in the presence of TX-100, due to the improved emission efficiency of PPEA in the presence of TX-100. Under optimum conditions, the detection range of Triton X-100 is between 1.0 ×10 ^-7 and 1.0 ×10 ^-4 mol·L ^-1, with a detection limit at 6.0×10 ^-8 moloL 1. The relative standard deviation is 2.4% (n=6) for 1.0×10 ^-6 mol·L ^-1Triton X-100. This method provides satisfying results in the detection of TX-100 in nature water and biological samples with high sensitivity and wide linear range.A novel peroxyoxalate chemiluminescence system has been designed for the determination of Triton X-100 (TX-100), in which a hydrophobic fluorescent conjugated polymer, poly[2,5-bisnonyloxy-1,4-phenyleneethynylene-9,10-anthrylene] (PPEA) was employed as a fluorophor. A strong enhanced intensity of chemiluminescence (CL) was observed in the presence of TX-100, due to the improved emission efficiency of PPEA in the presence of TX-100. Under optimum conditions, the detection range of Triton X-100 is between 1.0 ×10 ^-7 and 1.0 ×10 ^-4 mol·L ^-1, with a detection limit at 6.0×10 ^-8 moloL 1. The relative standard deviation is 2.4% (n=6) for 1.0×10 ^-6 mol·L ^-1Triton X-100. This method provides satisfying results in the detection of TX-100 in nature water and biological samples with high sensitivity and wide linear range.

关 键 词:peroxyoxalate chemiluminescence triton X-100 fluorescent conjugated polymers 

分 类 号:O631.24[理学—高分子化学] TQ171.12[理学—化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象