华能南京电厂300MW机组锅炉掺烧阳泉煤的试验研究  

Testing and Research on Burning Blended Yangquan Coal on 300 MW Boilers in Huaneng Nanjing Power Plant

在线阅读下载全文

作  者:王茂华[1] 李斌[1] 

机构地区:[1]华能南京电厂,江苏南京210035

出  处:《中国电力》1999年第11期17-21,共5页Electric Power

摘  要:通过对华能南京电厂2 台300 MW 机组锅炉掺烧阳泉煤的实验室研究和实炉掺烧试验,得到锅炉掺烧阳泉煤对运行可靠性和经济性的影响,并对产生这些影响的因素进行了简要分析。结果表明试验是成功的,扩大了燃煤范围并降低了成本,取得了很好的经济效益。Through laboratory research and on site testing on Yangquan coal blending firing on two 300 MW boilers in Huaneng Nanjing Power Plant,the impacts of coal blending firing on operation reliability and economics of boilers were obtained,and the factors leading to these impacts were briefly analyzed.The results showed that testing was successful,coal combustion ranges were expanded and cost was reduced with good economic benefit gained.

关 键 词:锅炉 可靠性 燃煤 电厂 

分 类 号:TK227.1[动力工程及工程热物理—动力机械及工程] TM621.2[电气工程—电力系统及自动化]

 