中低心率患者在双源CT低管电压冠状动脉成像中的图像质量及辐射剂量  被引量:7

Dual-source CT coronary angiography in patients with medium and low heart rate: imaging quality and radiation doses at a low tube voltage

在线阅读下载全文

作  者:胡永胜[1] 何新华[1] 付璇[1] 王自勇[1] 王慧[1] 陈昊[1] 费长军[1] 王劲武[1] 

机构地区:[1]合肥市第一人民医院医学影像中心,230061

出  处:《中华放射学杂志》2011年第3期279-283,共5页Chinese Journal of Radiology

摘  要:目的探讨中低心率对双源CT低管电压冠状动脉成像的图像质量及辐射剂量的影响。方法对85例体质量指数(BMI)为17.51~30.00kg/m2、心率在91次/min(bpm)以下的可疑冠心病患者进行双源CT低管电压(100kVp)回顾性心电门控冠状动脉成像增强扫描,检查前不使用β受体阻滞剂控制心率。按患者扫描时的心率进行分组,≤59bpm为A组(27例),60—69bpm为B组(29例),/〉70bpm为C组(29例)。评价各组的最佳重建时相图像,记录各组的增强扫描序列的螺距、CT容积剂量指数(CTDIvol)、剂量长度乘积(DLP)及有效剂量(ED)值。应用单因素方差分析比较3组患者的扫描螺距、图像质量评分和辐射剂量值等。分析心率对冠状动脉成像图像质量及辐射剂量的影响。结果A、B、C组螺距分别为0.241±0.025、0.286±0.034、0.335±0.036;3组图像质量评分分别为(4.78±0.26)、(4.66±0.56)、(4.70±0.46)分;CTDIvol值分别为(18.06±5.16)、(19.62±7.15)和(17.50±7.13)mGy,ED值分别为(4.23±1.16)、(4.59±1.75)、(4.12±1.39)mSv。3组的螺距差异有统计学意义(F=60.00,P=0.00);3组间的图像质量评分差异无统计学意义(F=0.53,P=0.59);3组间CTDIvol差异无统计学意义(F=0.83,P=0.44),ED差异也无统计学意义(F=0.86,P=0.43)。结论中低心率对双源CT低管电压冠状动脉成像的图像质量影响很小,在自动心电门控剂量窗时,对辐射剂量的影响也很小。Objective To evaluate the imaging quality and radiation doses of dual-source computed tomography (DSCT) coronary angiography at a low tube voltage in patients with medium and low heart rate . Methods Eighty-five patients [heart rate (HR) 〈91 beats per minute(bpm) ;body mass index(BMI) 17.51-30. 00 kg/m2] suspected of coronary artery disease received retrospectively ECG-gating coronary angiography with dual-source CT scanner (Somatom Definition, Siemens) at a tube voltage of 100 kVp. For all patients, no beta-blocker was used before CT scan. According to the HR, the patients were divided into three groups: Group A, HR ≤〈 59 bpm, n = 27; Group B, HR 60-69 bpm, n = 29; Group C, HR ≥70 bpm, n = 29. All images were transferred to a workstation for postprocessing. The best R-R interval reconstruction images of all groups were evaluated. The value of pitch, CT volume dosage index (CTDIvol), dose length product (DLP)and effective close (ED)were recorded. The pitch, the score of imaging quality of coronary artery segments and the radiation dose were compared with one-way ANOVA. The influence of HR on image quality and radiation doses of coronary artery was analyzed. Results The value of pitch in Group A, Group B and Group C was 0.241 ±0.025, 0.286 ±0.034 and 0.335 ±0.036, respectively. The mean score of imaging quality of coronary artery segments in Group A, Group B and Group C was 4. 78 ± 0. 26, 4. 66 - 0. 56 and 4. 70 ± 0. 46, respectively. The value of CTDIvoi in Group A, Group B and Group C was ( 18.06 ±5. 16), ( 19. 62 ±7. 15) and ( 17. 50 ±7. 13) mGy, respectively. The value of ED in group A, Group B and Group C was (4.23 ± 1.16), (4.59 ± 1.75) and (4.12 ± 1.39) rosy, respectively. There was statistical difference in value of pitch among the three groups ( F =60. 00, P = 0. 00). There were no statistical difference in score of imaging quality, CTDIvoI and value of ED among the three groups ( F=0. 53, P = 0. 59 ; F = 0. 83, P = 0. 44 ;

关 键 词:辐射剂量 冠状血管 体层摄影术 X线计算机 心率 

分 类 号:R816.2[医药卫生—放射医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象