检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]株洲工学院,株洲412008
出 处:《株洲工学院学报》1999年第4期34-35,55,共3页Journal of Zhuzhou Institute of Technology
摘 要:消防工程中的火灾自动报警系统在高层建筑中越来越成为必不可少的设备。介绍一套自行设计的火灾自动报警的计算机监控系统,计算机通过I/O接口电路对烟感、温感、差定温感及各消防设备状态的开关量输入信号进行检测,一旦有火警信号,计算机则通过显示器显示各楼层的平面分布图,火警的具体位置并能发挥各种管理功能。An automatic fire - alarm system becomes more and more necessary device used in high building. During the studying fire - control engineering for some fire - fingting companies the paper has develeped a new type of computer monitoring system in the design. Computer detect fume sensor, temperature sensor, temperatuer difference setted sensor, switching input signals of all kinds of fire - devices' status with I/O interfaces. When fire - alarms happen, computer displays the floor digram of the whole building and the fire - alarm position and man other managing functions. Three- yeare running shows the system has such advantages as high reliability, low cost,good functions and convenience.