检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:陈宇[1] 黎光武[1] 张刚[2] 张文慧[2] 闫果红[3] 顾先宝[1] 陈艳超[1]
机构地区:[1]中国原子能科学研究院,北京102413 [2]兰州大学,甘肃兰州730000 [3]山西师范大学,山西临汾041004
出 处:《原子能科学技术》2011年第4期491-494,共4页Atomic Energy Science and Technology
基 金:国家自然科学基金资助项目(10475068;10476018)
摘 要:用241 Amα源对裂变多参数实验中使用的平行板雪崩计数器(PPAC)进行了各探测单元时间分辨和位置分辨的系统测试。PPAC的工作气体为异丁烷,流气气压为600Pa,阴极工作电压为-600V。使用飞行时间法测得探测单元的时间分辨好于400ps,使用延迟线法得出位置分辨为6mm。结果表明,PPAC的性能满足实验需求。Systematic test on each detect unit of parallel plate avalanche counter(PPAC) used in the fission multi-parameter measurement was performed with a 241Am α source to get the time resolution and position resolution.The detectors work at 600 Pa flowing isobutane and with-600 V on cathode.The time resolution was got by TOF method and the position resolution was got by delay line method.The time resolution of detect units is better than 400 ps,and the position resolution is 6 mm.The results show that the demand of measurement is fully covered.
分 类 号:TL816.4[核科学技术—核技术及应用]