检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:余渊善[1] 徐柳婧[1] 宋扬[1] 白益波[1] 王威廉[1]
机构地区:[1]云南大学信息学院,昆明650091
出 处:《电子测量技术》2011年第4期81-85,共5页Electronic Measurement Technology
基 金:云南省大学生创新性实验计划项目(X3110008)
摘 要:心音信号(PCG)、心电信号(ECG)是人体重要的生理信号,携带大量生理特征,但这些微弱信号的提取极易受到外界的干扰。采用三导联的方式,利用仪用放大器AD623的优良特性提取心电信号,采用专用的集成心音传感器HKY-06B提取心音信号。另外,使用差分阀值的算法,通过心电信号可以精确地定位心音信号。系统采用+3 V电池供电,具有低功耗、低噪声和低电压的特点,为便携式设备和嵌入式系统的开发奠定了基础。PCG and ECG Signals which carrying a large number of physiological characteristics,are important physiological signals of the body.However the approach of PCG and ECG signal acquisition is extremely difficult.In this paper,we used a practical three-lead method and high performance Instrumentation Amplifier AD623 to collect ECG signal.The specified integrated sensor HKY-06B was used in the PCG signal acquisition.Additionally,Differential Positioning,this special method was applied to locate the PCG signal.This low-power single-supply and low-noise circuit system,power supply is +3 V(two batteries supply),which lays foundation for the development of embedded system and portable devices.
关 键 词:心音信号 心电信号 KRC有源滤波器 IIR陷波器 差分阀值定位
分 类 号:TP274.2[自动化与计算机技术—检测技术与自动化装置]