摘 要:目的:总结42例CT及电视透视导引下经皮胸部穿刺活检经验。方法:其中肺部病变31例;胸膜病变6例;纵隔肿块5例。采用改进后的18 号Cook 切割针在CT或电视透视导引下经皮穿刺活检。结果:一次穿刺成功率为94% ;确诊率为96% ;并发症发生率为12% 。结论:该方法获取组织较大,既可涂片作细胞学检查,又可切片作病理检查。Objective:To sum up the experience of 42 cases of percutaneous puncture biopsy of thorax under CT and TV fluoroscopy guided.Methods:31 cases were pulmonary lesions,6 had pleural lesions and 5 were mediastinal masses.Biopsy was done using improved Cook 18 cutting needle.Results:The successful rate by first puncture was 95% and the diagnostic rate was 94%.Conclusion:The incidence of complications was 12%.The larger tissues which may be used either for smearing and cytological examination or for section-cutting and pathological examination can be obtained by this method.