机构地区:[1]中山大学化学与化工学院,广州510275 [2]桂林工学院测试中心,桂林541004
出 处:《深圳大学学报(理工版)》1999年第2期89-93,共5页Journal of Shenzhen University(Science and Engineering)
摘 要:采用氢化物-原子荧光光谱法测定人体血液中硒的含量.健康者(30人)血液中硒的平均含量为114.6±11.2ng·mL^(-1);肿瘤及心脏病患者(20人)血液中硒的平均含量为77.4±11.1ng·mL^(-1)。研究结果表明:肿瘤及心脏病患者血液中硒的含量明显低于正常人.该方法的回收率为90.5%-107.0%,相对标准偏差为6.6%,检出极限为0.65ng·mL(-1).The determination of selenium in human blood by hydride - generation - atomic fluoresecence spectrometry (HG -AFS) is studied. HNO_3 - HClO_4 - HCl is used for sample pretreatment. The recoveries are from 90. 5% to 107. 0%, the detection lindt is 0. 65ng·mL^(-1), and the relative standard deviation (RSD) is 6.6%, Under optimized experimental conditions, selenium in human blood has been determined, The average concentration of Se is 114.6±11 .2ng·mL^(-1) for thirty healthy people, and 77 .4 ±11. 2ng·^(-1) for twenty patients. The resultS showed that the concentrafion of Se in the blood of a patient is lower than tha in a healthy person, and can be used for the clinical diagnosis.