酸化后原油电脱水困难原因分析  被引量:4

The Study of Electic Dehydration with Crude Oil

在线阅读下载全文

作  者:吴泽美[1] 孙玉民[1] 史贵生[2] 赵尚柱[1] 付亚荣[1] 

机构地区:[1]中石油华北油田分公司第五采油厂,河北辛集052360 [2]中石油华北油田分公司质量安全监督中心,河北任丘062552

出  处:《长江大学学报(自然科学版)》2011年第4期52-53,286,共2页Journal of Yangtze University(Natural Science Edition)

摘  要:华北油田第五采油厂H16井经过酸化后投产,排水排酸后产出液进入联合站处理,在电脱水过程中电脱水器频繁跳闸,至使原油电脱水困难。通过对比分析H16井原油及相邻区块原油的电导率,掌握了电脱水器跳闸的原因是酸化后原油虽然含水很低(<1%),但是电导率高,电脱水器工作电流超过额定值。通过加碱(NaOH)处理,混合液电导率下降,电脱水器恢复正常工作。The acidizing technique is often used for well reconstruction before production in a new oil well.Well H-16 was put into production after acidizing,then the electric dehydrator striped off frequently,the reason lies in the electric conductance of Well H-16 is rather higher,though the water cut of Well H-16 is very low(<1%).When the working current of the electric dehydrator isover the safe current,the electric dehydrator stoped to work.The electric conductance of liquid began to reduce after treating with sodium hydroxide,then the electric dehydrator returned to normal.

关 键 词:酸化 电脱水器 跳闸 电导率  