过硫酸钾消解-紫外分光光度法测定水中总氮的几点注意事项  被引量:7

Several Cautions in the Determination on Total Nitrogen in Water Sample with Potassium Persulfate Digestion-UV Spectrophotometer Method

在线阅读下载全文

作  者:曹轶男[1] 仪军[1] 刘晓荣[1] 王瑞菲[1] 

机构地区:[1]辽宁省安全科学研究院,辽宁沈阳110004

出  处:《山东化工》2011年第5期40-41,共2页Shandong Chemical Industry

摘  要:经实验证明,过硫酸钾消解-紫外分光光度法测定水中总氮过程中,用超纯水代替无氨水方便可行;在实验确定的最佳条件下对样品进行测定,结果准确可靠;同时就实验中的细节问题作了补充。It was proved by the experiment that in the process of determination on total nitrogen in water sample with potassium persulfate digestion - UV spectrophotometer method, it was convient and feasible to use ultra - pure water instead of ammonia - free. Under the optimum conditions, the sample was determined and the result was accurate and reliable; meanwhile the details of the experiment was added.

关 键 词:总氮 过硫酸钾消解 紫外分光光度法 

分 类 号:O657.32[理学—分析化学]

 