北京市大兴区13家公共场所军团菌监测  被引量:3

Legionella Surveillance in 13 public places of Daxing District,Beijing

在线阅读下载全文

作  者:周丽敏[1] 王斌[1] 

机构地区:[1]北京市大兴区疾病预防控制中心,北京102600

出  处:《中国卫生检验杂志》2011年第6期1497-1499,共3页Chinese Journal of Health Laboratory Technology

摘  要:目的:选择13家使用中央空调系统的大型公共场所进行军团菌检测。方法:采集监测单位中央空调系统冷却塔水样进行军团菌分离、鉴定和计数。结果:13家单位共采集104件冷却塔水样,在5家场所(38.4%)的水样中检出嗜肺军团菌16株,检出数占样品总数的15.38%。结论:应加大监管力度,督促对中央空调进行清洗消毒。Objective:Selecting 13 large-scale places using central air conditioning system to test their Legionella contamination.Methods: Collecting monitoring samples to carry on Legionella isolation,identification and counting.Results: In the 104 cooling tower water samples from 13 places,16 Legionella pneumophila strains(15.38%) in five places(38.4%) were detected.Conclusion: We should strengthen supervision and carry out the central air-conditioning units cleaning and disinfecting.

关 键 词:军团菌 公共场所 

分 类 号:R126.4[医药卫生—环境卫生学]

 