Chemiluminescence determination of melamine with Luminol-K_3Fe(CN)_6 system  被引量:2

Chemiluminescence determination of melamine with Luminol-K_3Fe(CN)_6 system

在线阅读下载全文

作  者:Xiao- Shuang Tang Xi-Yan Shi Yu-Hai Tang Zhong-Jin Yue Qi-Qi He 

机构地区:[1]The Second Affiliated Hospital, Lanzhou University, Lanzhou 730030, China [2]Institute of Analytical Sciences, Xi'an Jiaotong University. Xi'an 710061, China.

出  处:《Journal of Pharmaceutical Analysis》2011年第2期104-107,共4页药物分析学报(英文版)

摘  要:A sensitive chemiluminescence(CL) method was developed for determining melamine in urine and plasma samples based on the fact that melamine can remarkably enhance the chemiluminescence of Luminol-K3 Fe(CN)6 system in alkaline medium. The determination conditions were optimized. Under optimum conditions, the chemiluminescence intensity had a good linear relationship with melamine in the range of 9.0 × 10^-9 - 7.0 × 10^-6 g/mL with a correlation coefficient of 0. 9992. The detection limits (3o) were 3.54 ng/mL for urine sample and 6.58 ng/mL for plasma sample. The average recoveries of melamine were 102.6% for urine sample and 95.1% for plasma sample. Melamine in samples was extracted with liquid-liquid extraction procedures and the assay results coincided very well with that determined with flow injection chemiluminescence method. The method provides a reproducible and stable approach for sensitive detection and quantification of melamine in urine and plasma samples.A sensitive chemiluminescence(CL) method was developed for determining melamine in urine and plasma samples based on the fact that melamine can remarkably enhance the chemiluminescence of Luminol-K3 Fe(CN)6 system in alkaline medium. The determination conditions were optimized. Under optimum conditions, the chemiluminescence intensity had a good linear relationship with melamine in the range of 9.0 × 10^-9 - 7.0 × 10^-6 g/mL with a correlation coefficient of 0. 9992. The detection limits (3o) were 3.54 ng/mL for urine sample and 6.58 ng/mL for plasma sample. The average recoveries of melamine were 102.6% for urine sample and 95.1% for plasma sample. Melamine in samples was extracted with liquid-liquid extraction procedures and the assay results coincided very well with that determined with flow injection chemiluminescence method. The method provides a reproducible and stable approach for sensitive detection and quantification of melamine in urine and plasma samples.

关 键 词:CHEMILUMINESCENCE flow injection MELAMINE URINE PLASMA 

分 类 号:O657.3[理学—分析化学] TQ226.62[理学—化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象