温湿度独立控制系统在办公楼中的应用及运行效果  被引量:4

The application and running effect of the temperature and humidity independent control system in the office building

在线阅读下载全文

作  者:朱颖秋[1] 王嘉[1] 马晓钧[1] 诸群飞[1] 

机构地区:[1]北京市建筑设计研究院

出  处:《供热制冷》2011年第3期66-70,共5页Heating & Refrigeration

摘  要:本文阐述了北京市建筑设计研究院F座办公楼空调系统组成及运行方式,通过实测数据对其室内空气质量进行评估,并通过建筑能耗模拟软件Dest对该楼采用的空调系统和普通空调系统的能耗进行比较。结果表明该楼所采用的空调系统具有较好的节能效果和较高的热舒适性。This paper describes the air conditioning system and its running method of the office building F in Beijing Institute of Architectural Design. The indoor air quality is evaluated by measured data. The energy consumption of the real air conditioning system are compared with the conventional air conditioning system by building energy simulation software. The results indicate that the temperature and humidity independent control system have better effects on energy conservation and heat comfort.

关 键 词:温湿度独立控制 辐射吊顶 地板送风 溶液除湿 节能 

分 类 号:TU243[建筑科学—建筑设计及理论]

 