Anatomical and biomechanical study on the interosseous membrane of the cadaveric forearm  被引量:1

Anatomical and biomechanical study on the interosseous membrane of the cadaveric forearm

在线阅读下载全文

作  者:YI Xian-hong PAN Jun GUO Xiao-shan 

机构地区:[1]Department of Orthopaedics, Second Affiliated Hospital of Wenzhou Medical College, Wenzhou 325027, China

出  处:《Chinese Journal of Traumatology》2011年第3期147-150,共4页中华创伤杂志(英文版)

摘  要:Objective: To study the anatomical and biomechanical features of the interosseous membrane 0OM) of the cadaveric forearm. Methods: Ten radius-IOM-ulna structures were harvested from fresh-frozen cadavers to measure the length, width and thickness of the tendinous portion oflOM. Then, the tendinous portion was isolated along with the ulnar and radial ends to which the tendon attached after measurement. The proximal portion of the radius and the distal portion of the ulna were embedded and fixed in the dental base acrylic resin powder. The embedded specimen was clamped and fixed by the MTS 858 test machine using a 10 000 N load cell for the entire tensile test. IOM was stretched at a speed of 50 mm/min until it was ruptured. The load-displacement curve was depicted with a computer and the maximum load and stiffness were recorded at the same time. Results: The IOM of the forearm was composed of three portions: central tendinous tissue, membranous tis-sue and dorsal affiliated oblique cord. IOM was stretched at a neutral position, and flexed at pronation and supination positions. The tendinous portion of IOM was lacerated in 6 specimens when the point of the maximum load reached to 1 021.50 N± 250.13 N, the stiffness to 138.24 N/m±24.29 N/m, and the length of stretch to 9.77 mm±l.77 mm. Fracture occurred at the fixed end of the ulna before laceration of the tendinous portion in 4 specimens when the maximum load was 744.40 N±109.85 N, the stiffness was 151.17 N/m±30.68 N/m, and the length of the stretch was 6.51 mm±0.51 mm. Conclusions: The IOM of the forearm is a structure having ligamentous characteristics between the radius and the ulna. It is very important for maintenance of the longitudinal stability of the forearm. The anatomical and biomechanical data can be used as an objective criterion for evaluating the reconstructive method of IOM of the forearm.

关 键 词:FOREARM ANATOMY BIOMECHANICS 

分 类 号:U461.91[机械工程—车辆工程] Q944.5[交通运输工程—载运工具运用工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象