作 者:马晓珑[1] 陈书平[2] 李学忠[3] 张晟[2] 高景辉[1] 寿兵[3] 杨博[1] 伍刚[1]
机构地区:[1]西安热工研究院有限公司,陕西西安710032 [2]华能国际电力股份有限公司,北京100031 [3]华能海门电厂,广东汕头515100
出 处:《热力发电》2011年第6期75-78,共4页Thermal Power Generation
摘 要:针对某电厂超超临界1 000 MW机组锅炉引风机与脱硫增压风机合并后采用小汽轮机驱动引风机,分析汽动引风机对电厂主要运行指标的影响。分析结果表明,大容量风机采用小汽轮机驱动后,避免了风机起动过程中对厂用电系统的冲击,显著降低了厂用电率。After merging the induced draft fan(IDF) of boiler with the booster air fan used for flue gas desulphurization of ultra-supercritical 1000 MW unit in one power plant,a small-turbine driven IDF has been adopted.The influence of turbine-driven IDF upon main operating indices of power plant has been analysed,results of analysis show that the adoptation of turbine driven large-capacity IDF can avoid impulse to the auxiliry electric system in start-up process of IDF,reducing substantially the consumption rate of service power.
关 键 词:超超临界 1000MW机组 汽动引风机 小汽轮机 厂用电率 煤耗
分 类 号:TK223.26[动力工程及工程热物理—动力机械及工程]