地源热泵地埋管周围土壤温度特性研究  被引量:1

Research on soil temperature characteristics around vertical buried pipe of ground source heat pump

在线阅读下载全文

作  者:张行洋[1] 周亚素[1] 赵利君[1] 刘世昊[1] 李扬[1] 

机构地区:[1]东华大学

出  处:《制冷与空调》2011年第3期43-47,23,共6页Refrigeration and Air-Conditioning

摘  要:针对地源热泵系统在夏热冬暖地区长期运行可能引起的地下温度场热量累积问题,提出地源热泵系统通过制冷、停机和制热3种工况的交替运行这一解决措施。采用有限长线热源模型,并利用迭加原理,对钻孔不同深度处、距离钻孔中心不同半径处及不同运行策略下U形埋管地下换热器周围温度场的变化进行研究。对指导地源热泵系统的工程运用具有实用价值。For heat accumulation in underground temperature field caused by the ground source heat pump system being in long-term operation in hot summer and warm winter zone,puts forward the solution that the ground source heat pump system is operated alternately under cooling,shut-down and heating conditions.Using the limited long-term heat source,and superposition principle,studies the underground temperature field around U-tube heat exchanger on different drilling depth,distance from the drilling center and operation strategies.The result has practical value for guiding engineering application of the ground source heat pump system.

关 键 词:地源热泵 交替运行 有线长线热源 迭加原理 