检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
出 处:《电子技术应用》2011年第7期71-74,共4页Application of Electronic Technique
摘 要:神经肌肉疾病评估系统的关键是能同时准确提取幅值和相位信息。利用AD8302的高度集成特性设计了一种幅相测量电路。给出了电路原理图,详细论述了测量频率为50 kHz时,幅相测量电路设计的具体方法。性能分析结果表明,幅值和相位的测量性能与额定值比较接近。在±20 dB范围内,幅值测量精度在±0.5 dB以内;在±90°范围内,相位测量精度在±0.9°以内。Accurately picking up amplitude and phase at the same time is essential for neuromuscular disease assessment system. Based on the feature of highly integration of AD8302, a circuit to measure amplitude and phase was designed in this research, and the schematic diagram was provided. The method of circuit design was provied in detail with the frequency of 50 kHz. As a result of performance analysis of this system, the measured value of amplitude and phase is approach to rated value: 0.5 dB accuracy was achieved over a 20 dB range when measuring gain. Phase accuracy was 0.9° for a 90° range.
分 类 号:TP606[自动化与计算机技术—控制理论与控制工程]