作 者:ZHOU Feng TIAN Xin MA GuoYuan
出 处:《Chinese Science Bulletin》2011年第20期2185-2190,共6页
基 金:supported by the National Natural Science Foundation of China(51076003);the Specialized Research Fund for the Doctoral Program of Higher Education(200800050010);the Innovation Program for the Doctoral Students of Beijing University of Technology(bcx-2009-049)
摘 要:A data center test model was used to analyze the energy dissipation characteristics and energy consumption of a data center.The results indicate that adequate heat dissipation from a data center cannot be achieved only from heat dissipation through the building envelope during Beijing winter conditions.This is because heat dissipation through the building envelope covers about 19.5% of the total data center heat load.The average energy consumption for an air conditioner is 4 to 5 kW over a 24-h period.The temperature difference between the indoor and outdoor air for the data center with a thermosyphon heat exchanger is less than 20°C.The energy consumption of the thermosyphon heat exchanger is only 41% of that of an air conditioner.The annual energy consumption can be reduced by 35.4% with a thermosyphon system.In addition,the effect of the outdoor temperature on the en-ergy consumption of an air conditioner is greater than the indoor room temperature.The energy consumption of an air conditioner system increases by 5%to 6%for every 1°C rise in the outdoor temperature.A data center test model was used to analyze the energy dissipation characteristics and energy consumption of a data center.The results indicate that adequate heat dissipation from a data center cannot be achieved only from heat dissipation through the building envelope during Beijing winter conditions.This is because heat dissipation through the building envelope covers about 19.5% of the total data center heat load.The average energy consumption for an air conditioner is 4 to 5 kW over a 24-h period.The temperature difference between the indoor and outdoor air for the data center with a thermosyphon heat exchanger is less than 20°C.The energy consumption of the thermosyphon heat exchanger is only 41% of that of an air conditioner.The annual energy consumption can be reduced by 35.4% with a thermosyphon system.In addition,the effect of the outdoor temperature on the en-ergy consumption of an air conditioner is greater than the indoor room temperature.The energy consumption of an air conditioner system increases by 5%to 6%for every 1°C rise in the outdoor temperature.
关 键 词:数据中心 能源消耗 热虹吸管 换热 空调系统 围护结构 室外空气 能量耗散
分 类 号:TK172[动力工程及工程热物理—热能工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.117