摘  要:考虑几何非线性和面外初始缺陷,通过变化内嵌钢板的高厚比λ,考察了钢板墙与防屈曲组合钢板墙在水平荷载作用下的承载力、抗侧刚度和滞回性能的差异,并对比分析了两种墙体的内嵌钢板与边缘框架柱的相互作用。结果表明,随λ由大到小变化,钢板墙可分为薄钢板墙、中厚钢板墙和厚钢板墙三类;由于受到面外约束的作用,与钢板墙相比,防屈曲组合钢板墙具有更好的抗剪承载力和耗能能力,利用防屈曲组合钢板墙替代中厚钢板墙和薄钢板墙是经济可行的,且不存在因屈曲后拉力场效用对边柱产生的附加弯矩作用,更有利于实现"强框架弱墙体"的延性设计。Buckling-restrained composite steel plate shear wall(BR-CSPW) is a new type of earthquake-resisting element.With varying height-to-thickness ratio λ of the steel plate,the shear performance of BR-CSPW and steel plate shear wall(SPW) under shear loading is studied by means of nonlinear finite element analysis using ABAQUS software.Large-deflection effect and out-of-plane initial imperfection are taken into account.To further identify the effect of internal force on the behavior of boundary column,interaction between steel plate and boundary column of BR-CSPW and SPW is also investigated.The results show that,according to different λ,SPW can be categorized into three groups-thin SPW,medium thickness SPW and thick SPW;BR-CSPW resists the story shear by yielding in shears,and has relatively much higher shear capacity and energy dissipation capacity,which indicates that Using BR-CSPW instead of thin SPW and medium thickness SPW is feasible and won't cause the adverse effect of diagonal tension field action on the boundary column,as a result,is more advantageous to the desire for ductile design criterion of strong boundary frame-weak steel plate wall.

关 键 词:钢板墙 防屈曲组合钢板墙 高厚比 受剪性能 滞回性能 

分 类 号:TU392.4[建筑科学—结构工程] TU312

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象