检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]华南理工大学自动化科学与工程学院,广州510640
出 处:《制冷》2011年第2期21-26,共6页Refrigeration
摘 要:本文以广州某大厦水冷型中央空调系统为例子,利用Trnsys建立了大厦某层的多区域建筑及其中央空调系统能耗仿真模型,在此基础上分析加控制和不加控制两种情况下中央空调能耗情况。由两种模型的仿真结果可知中央空调具有很大的节能空间。模型主要用于研究中央空调运行的一些性质,对中央空调的节能优化控制具有重要的意义。In this paper, a water- cooled central air conditioning system of a building in Guangzhou is taken for an exampie to establish the simulation models of one of the building's layers and its central air conditioning systems, on the basis of a controlled and uncontrolled cases, the energy consumption is analyzed. The simulation results from the two models show that there is a great space of energy - saving of central air conditioning system. This model is mainly used to study some properties of the central air conditioning and is of great significance to energy - saving optimal control of central? air conditioning.
分 类 号:TU831[建筑科学—供热、供燃气、通风及空调工程] TQ018[化学工程]