摘  要:可燃气体检测报警器检定中示值误差检定、重复性检定、报警误差检定和漂移检定等检测点较多,重复计算量大,要牵涉到繁琐的计算和判断,这些计算费时又费力,给检测结果的处理带来了不少困难,同时效率也比较低。介绍了如何利用电子表格处理报警器检测结果,解决了日常工作中检测数据多,手工计算繁杂的问题。There are many testing points in the determination of flammability gas annunciators, including the determination of indication error, repeatability, alarm error and drift. So a great number of repetitive works involve the complex calculations and judgments. These calculations which not only spend a lot of time, but also have to make a great effort, have brought about a lot of difficulties to the processing of testing results, and have lower efficiency. The paper mainly studies how to process the testing results of annunciators by the utilization of Excel, and thus solves the problem of numerous testing data and complicated manual calculation in the routine work.