热气旁通在空气源热泵机组中的应用  被引量:9

The Use of Hot Gas Bypass in Air Source Heat Pump

在线阅读下载全文

作  者:秦素梅 

机构地区:[1]中国建筑科学研究院建筑环境与节能研究院,北京100013

出  处:《机电产品开发与创新》2011年第4期32-33,38,共3页Development & Innovation of Machinery & Electrical Products

摘  要:空气源热泵机组是以空气为热源,它可以在炎热季节实现制冷,寒冷季节实现制热,从而省去了冷却水系统以及锅炉等设备。但其低压和结霜的问题一直是制约其应用的一个重要因素。对空气源热泵机组的工作原理进行了讨论,分析了其形成低压和结霜的原因,对热气旁通技术进行了讨论,阐述了其在解决空气源热泵机组两大主要问题方面的应用,并通过实验证明其有效性。Air source heat pump is the air as the heat source,it can be in the hot season of refrigeration,heating to achieve the cold season,thus eliminating the need for cooling water systems and boilers and other equipment.But the issue has been low and frost is a major restricting factor in their application.Air source heat pump works were discussed,analyzed the reasons for the formation of low pressure and frost on the hot gas bypass techniques are discussed,described its air source heat pump units in solving two major problems in the application,and Experiments prove its effectiveness.

关 键 词:热气旁通 空气源热泵机组 除霜 

分 类 号:TM925.1[电气工程—电力电子与电力传动]

 