摘 要:将通信电源集中监控技术应用在通信电源中,能实时监视电源设备的工作状态,并能够实时显示采集的各种监测数据和告警信息,同时与监控中心实现无线通信,实时地向监控中心转发这些监测数据和告警信息。本文对基于无线传输的通信电源的监测系统进行了研究,设计了一套利用红外传输的管理监测系统,讨论了影响数据无线传输可靠性的因素,给出了系统的软、硬件设计,并对实验结果进行了分析。The application of the concentration of communication power monitoring technology in communications,marks it realized that can real-time monitor the working status of power equipment and display all the collected monitoring data and warning information.Meanwhile,it is able to realise wireless communication with the control center,and immediately send the monitoring data and alarm information to control center.In this paper,through the research of communication power monitoring system based on wireless transmission,I designed a set of infrared transmission management monitoring system and discuss the effect factors of data transmission.Moreover,the software and hardware of the system design was put forwarded.The results of experiment was also analyzed in the paper.