环境对气体注入法测量剩余推进剂的影响分析  被引量:5

Analysis of Effect of Ground and Space Environment on Propellant Gauging with Gas Injection Method

在线阅读下载全文

作  者:宋涛[1] 马云华[1] 林长杰[1] 梁军强[1] 魏延明[1] 

机构地区:[1]北京控制工程研究所,北京100190

出  处:《航天器工程》2011年第4期147-151,共5页Spacecraft Engineering

摘  要:为提高在轨剩余推进剂测量精度,根据气体注入法测量推进剂剩余量的原理,结合地面试验情况,针对地面试验和卫星在轨的环境差异对测量结果的影响进行了分析,结果表明:气体注入法的地面试验结果能够反映在轨实施的测量情况;在轨环境与地面环境的差异对于温度测量的影响,可以通过延长试验的测量时间和增加测温点等手段加以消除。To improve the precision of the remaining propellant gauging in space,based on the theory of gas injection method for remaining propellant gauging,a ground test of propellant gauging system is carried out.In this paper,the effect on the result of propellant gauging is analysed which is caused by the difference between the in-orbit environment and the ground one.It is confirmed that the ground test result of gas injection method can represent the precision of on-orbit implementation.The error of the temperature measure,which is caused by the difference between the on-orbit environment and the ground one,can be decreased by extending the test time and increasing the temperature measure points.

关 键 词:卫星 推进剂剩余量测量 气体注入法 地面试验 在轨实施 差异分析 

分 类 号:V51[航空宇航科学与技术—航空宇航推进理论与工程]

 