摘 要:对变电站直流系统磷酸铁锂蓄电池应用的几个主要问题进行了讨论,阐述了直流系统磷酸铁锂蓄电池运行对于环境零污染、安全性、蓄电池使用寿命几个关键指标特性进行了分析,对比了目前变电站直流电源配置的阀控密封铅酸蓄电池各项指标,提出了磷酸铁锂蓄电池逐步替代铅酸蓄电池可行性方案,以及今后一体化电源、智能电网新技术的推广应用。In this paper,several major problems about the application of the lithium iron phosphate battery in substation DC system were discussed.Several key index characteristics,environmental zero pollution,safety and the service life about the lithium iron phosphate battery were analyzed.The comparison between the valve-control sealed lead-acid battery and the lithium iron phosphate battery was carried out.The feasibility application method was put forward that lithium iron phosphate battery replaced the valve-control sealed lead-acid battery gradually,as well as the application of the new technology in integration power supply and intelligent grid in the future.
关 键 词:磷酸铁锂蓄电池 阀控密封铅酸蓄电池 变电站 直流电源系统