机构地区:[1]中冶京诚工程技术有限公司,北京100176 [2]中冶建筑研究总院有限公司,北京100088
出 处:《环境工程》2011年第4期121-124,共4页Environmental Engineering
摘 要:介绍了钢铁行业的高炉煤粉喷吹站消防水系统总的设计原则、设计方法,并针对某钢铁联合企业两座1 780 m3高炉合建的煤粉喷吹站消防水系统设计的工程实例,详细论述了高炉煤粉喷吹站消防水系统的选择方法、组成部分、主要参数的确定方法及控制方法。同时结合工程实践,对高炉煤粉喷吹站消防水系统设计中常遇到的一些问题提出了合理建议。It is introduced that the general design principle and the design method of the fire fighting system of blast furnace coal powder injection station for ironand steel industry.Aiming at a design of the fire fighting water system of a coal powder injection station for two 1 780 m3 blast furnaces,it is discussed in detail the choice method,constituent,method of determining the main parameter,and control method of the system.Combining with the engineering practice in the meantime,it is also put forward some reasonable suggestions on the fire fighting system of blast furnace coal powder injection station.