等离子体原子发射光谱测定饲料中磷和硫  被引量:1

The detection of phosphorus and sulphur content in feed by plasma-atomic emission spectrometry

在线阅读下载全文

作  者:张喜琦[1] 胡梅[1] 王骏[1] 张娟[1] 

机构地区:[1]山东省产品质量监督检验研究院,山东济南250100

出  处:《粮食与饲料工业》2011年第9期60-62,共3页Cereal & Feed Industry

摘  要:试验采用微波消解进行样品处理,再用等离子体原子发射光谱法对饲料中的磷和硫进行同时测定。磷和硫测定的精密度分别为1.07%~2.62%和1.70%~3.35%,加标回收率分别为99.2%~100.8%和97.3%~101.6%;样品测定结果同国家标准方法一致,对相关国家标准物质的测定结果与标准值相吻合。ABSTRACT:After the microwave digestion pretreatment, we determined the tJhosphol us and sull?imr ~'ontcut m tc,'d 1~3 t,la~,m~: atomic emission spectrometry. The determinalion precision of i~}l^q*horus ;llld s^dI~}ltlr w^l~: /. (,17~)4 "" ~. 62}CJ ~md ~. 71}~.; 3. 3,:~ Y~ , respectively; The recovery were 99.2~~ 100.8}{{ ~llld 97. 31, _ /~, - 101. (i~'~;, rt.spe^tiv~'ly.'['hc dt.l〈frnlnalion rcsuhs ~J samples was consistent with thai by national standard method, ai^d th~ dctt ,ruination result〉 of relevfmt tmtional stamla,d ,nat,〉 rial coincided with the standard value.

关 键 词:微波消解 等离子体原子发射光谱 饲料   

分 类 号:S816[农业科学—饲料科学] O657.31[农业科学—畜牧学]

 