摘  要:针对环境水源现状,提出采集凝固热热泵系统为建筑物供热的新思路.凝固换热器是该系统的关键设备之一,在介绍凝固换热器原理的基础上,对连续提取凝固热的参数条件及流动阻力问题进行了分析,所得结论将为该热泵系统的研究提供有益参考.According to the condition of the environmental water, a new heat pump system named heat pump system with freezing latent heat collection was brought out for the heating in the buildings. In this new system, the freezing latent heat exchanger was one of the important devices. The principle and structure was introduced, the running parameters and flow resistance were analyzed. And the results would play a good role in the development of the new heat pump system.

关 键 词:热泵系统 凝固热 连续取热 流动阻力 参数 

分 类 号:TU831.6[建筑科学—供热、供燃气、通风及空调工程]

 