检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]广东工业大学自动化学院,广东广州510006 [2]中国南方电网科学研究院,广东广州510080
出 处:《电力自动化设备》2011年第10期56-60,共5页Electric Power Automation Equipment
摘 要:提出一种电力系统稳定器(PSS)参数优化整定方法:以机组有补偿相位特性在整个低频段满足要求为目标,确定PSS相位补偿环节时间常数;在临界增益法的基础上,以振荡过程中机组电磁功率振荡最小为目标,整定PSS控制增益;采用最大-最小蚁群算法求解优化模型。采用该方法,基于机组实测无补偿相位特性,对南方电网辖区多台机组PSS参数进行了校核与整定,验证了方法的有效性。A PSS(Power System Stabilizer) parameter optimization method is proposed,which determines the time constants of PSS phase compensation to meet the requirement of unit compensated phase characteristics in low frequency band and tunes the PSS control gain based on critical margin method to obtain the minimum oscillation of unit electromagnetic power. The maximum-minimum ant system is used to solve the optimization model. It is based on the unit uncompensated phase characteristics measured on site. The PSS parameters of some units in Southern China Power Grid are checked and tuned by the proposed method, which verifies its effectiveness.