作 者:周树仁[1] 彭幼林[1] 王建莉[1] 程永佳[1]
机构地区:[1]解放军251医院医学工程科,河北张家口075000
出 处:《医疗卫生装备》2011年第9期111-112,共2页Chinese Medical Equipment Journal
摘 要:目的:研究烧伤病房空气净化消毒洁净度的质量控制。方法:选择层流、静电和紫外线消毒烧伤病房各一间,分别在开机前、消毒后进行采样做空气培养和微粒检测。结果:层流烧伤病房细菌数明显少于静电和紫外线消毒烧伤病房。结论:烧伤病房层流净化消毒是一种理想的空气净化消毒方式,是实现烧伤病房现代化管理目标的重要设施之一。Ojective To study the quality control of air purification disinfection cleanliness in burn ward.Methods Three burn wards are selected including laminar flow,electrostatic and ultraviolet disinfection respectively.Sampling,air cultivation and particle detection were performed before starting and after disinfection.Results The number of bacteria in laminar flow burn wards is obviously less than wards with electrostatic and ultraviolet disinfection.Conclusion Laminar purification disinfection of burn ward is an ideal air disinfection way,which is is one of the important facilities to realize the modernization management target in burn ward.
关 键 词:烧伤病房 层流净化 静电消毒 紫外线消毒 质量 控制
分 类 号:R187[医药卫生—流行病学] TU246.11[医药卫生—公共卫生与预防医学]