摘  要:将风险理论应用于交直流混联电力系统的电压稳定分析中,结合电压崩溃发生的概率和产生的后果,定量地求取了不同负荷水平下系统发生电压崩溃的风险程度,并探讨了直流输电容量和直流控制方式对交直流混联电力系统电压崩溃风险的影响。通过确定SVC最佳无功补偿容量的实例,说明电压崩溃风险评估方法在协调电力系统安全性与经济性方面的独特优势和应用前景。Risk theory is applied to AC-DC power system voltage stability analysis. By integrating the probability of voltage collapse and its consequence, we calculate the voltage collapse risk of power system on various load levels. Then, the influence of different transmission capacity and control modes of DC lines on the voltage collapse risk is discussed. Fi nally, an example of optimized capacity of SVC demonstrates that the voltage collapse risk assessment method may contribute to coordinating the security and economy of power systems and be widely applied prospect.