低压发电机预防性试验技术研究  

On Preventive Test Technology of Voltage Generator

在线阅读下载全文

作  者:姜美武 

机构地区:[1]江山市峡口水电站,浙江江山324116

出  处:《浙江水利水电专科学校学报》2011年第3期28-31,共4页Journal of Zhejiang Water Conservancy and Hydropower College

摘  要:通过对小水电站低压水轮发电机预防性试验开展情况的调研,指出在具体实际试验中,缺乏针对性依据、不利于现场实施等方面所存在的问题.结合实际案例,就低压发电机预防性试验的一般项目、检测周期、检测要求、试验结果评价等展开分析、论证,提出了切实可行的观点及解决方法,并作出补充性建议参考标准.进一步促进小水电发电机预防性试验技术水平.The existing problems in actual test are pointed out in the paper, combined with the investigation on preventive testing of low pressure turbine generator in small hydropower stations. The aspects concerned with the preventive test for low voltage generator, such as regular projects, test cycle, detection requirements, test result evaluation and so on are analyzed and discussed based on the actual cases, and practical ideas and solutions are also put forward for reference in order to promote the preventive testing technology for small hydropower generators.

关 键 词:低压发电机 预防性试验技术 试验项目 试验标准 

分 类 号:TV734[水利工程—水利水电工程]

 