Fenton氧化法预处理喷涂车间有机废气吸收尾液  被引量:3

Study on the pretreatment of organic waste gas absorbing tail washings in spray finishing workshops by Fenton oxidation process

在线阅读下载全文

作  者:戴琴[1,2] 岑超平[1] 罗建中[2] 陈定盛[1] 雷育涛[1] 

机构地区:[1]环境保护部华南环境科学研究所,广东广州510655 [2]广东工业大学环境科学与工程学院.广东广州510006

出  处:《工业水处理》2011年第10期28-30,共3页Industrial Water Treatment

基  金:广东省科技计划项目重大专项(2007A032301001);粤港关键领域重点突破项目(东莞专项)(2007168502)

摘  要:根据喷涂车间有机废气吸收尾液难生物降解的特点,采用Fenton试剂氧化预处理,考察了H2O2和Fe^2+浓度、pH、反应时间等因素对去除效果的影响。在H2O2投加量为1.4mol/L,FeSO4·7H2O投量为62.3mmol/L,pH为7.4,反应3h的条件下,初始COD为40000+45000mg/L的含丙酮、乙酸乙酯、二甲苯的有机废气吸收尾液的COD去除率可达到78%。结果表明,Fenton试剂对该废水可以取得很好的预处理作用。Fenton pretreatment has been used for treating organic gas absorbing wastewater in spraying-painting workshop treatment. The effects of the concentrations of H2O2 and FeSO4.7H2O, pH, reaction time and other factors on the removal rate are investigated. When the reaction conditions are as follows :the dosage of H2O2 is around 1.4 tool/L, dosage of FeSO4.7H20 62.3 mmol/L, pH 7.4, and reaction time 3 h, the COD of the organic gas absorbing tail washings,whose initial COD is 40 000-45 000 mg/L containing acetone, ethyl acetate and dimethylbenzene, can reach 78%. The results show that Fenton reagent has very good effect on the pre-treatment of wastewater.

关 键 词:FENTON试剂 预处理 有机废气 吸收尾液 难生物降解 

分 类 号:X703.1[环境科学与工程—环境工程]

 